Withdrawable switchgear trucks are designed for primary circuit connection, isolation, measurement and protection-related applications in medium-voltage switchgear systems.
TOONICE provides voltage transformer trucks, isolation trucks and metering trucks for different switchgear configurations and project requirements.
Truck dimensions, primary contacts, secondary interfaces and interlocking arrangements are configured according to switchgear design and project specifications.
Withdrawable voltage transformer trucks integrate voltage transformers, primary fuses and associated components for voltage measurement and protection applications in medium-voltage switchgear.
Voltage Measurement
IEC 61869-3 / IEC 62271-200
Project-Based
Up to 40.5 kV
Withdrawable isolation trucks are designed for primary circuit connection and isolation functions in medium-voltage switchgear systems, providing safe isolation for inspection and maintenance.
Connection / Isolation
IEC 62271-200
Project-Based
Up to 40.5 kV
Withdrawable metering trucks integrate instrument transformers and metering interfaces according to project-specific measurement and metering requirements.
Metering & Revenue Measurement
IEC 61869 Series / IEC 62271-200
VT / CT / Project-Specific
Up to 40.5 kV
Documents available for project review and engineering coordination.
TOONICE provides voltage transformer trucks, isolation trucks and metering trucks for medium-voltage withdrawable switchgear up to 40.5 kV.
Voltage transformer trucks integrate voltage transformers, primary fuses and associated components for voltage measurement and protection. Metering trucks integrate instrument transformers (VT / CT) and metering interfaces for revenue metering and power measurement according to project-specific metering requirements.
Isolation trucks provide primary circuit connection and isolation in medium-voltage switchgear. When withdrawn, they create a safe isolation point for inspection and maintenance. They are not designed to switch load or fault currents and are operated under the switchgear interlocking scheme.
Yes. Truck dimensions, primary contacts, secondary interfaces and interlocking arrangements can be configured according to switchgear design and project specifications.
Available documents may include drawings, technical data sheets, interface dimensions, inspection records and certificates according to project requirements.
Access product catalogues and technical documents for product selection and project review.
Download Product CatalogueShare your voltage level, application and project requirements.
Thank you for your inquiry.
Our team will review your requirements and get back to you!