RELIABLE POWER FOR A SUSTAINABLE FUTURE

Oil-Immersed Transformers

Oil-immersed transformers engineered for utility, industrial and infrastructure power distribution applications, with project-specific voltage, capacity, impedance and connection arrangements.

Available in sealed-tank and conservator-type configurations, with transformer design, accessories, protection and monitoring arrangements configured according to project requirements and applicable IEC standards.

Key Ratings

  • Primary Rated Voltage

    Up to 35 kV

  • Transformer Capacity

    100 kVA – 10 MVA

  • Phase

    Three-Phase

  • Cooling Method

    ONAN

  • Rated Frequency

    50 / 60 Hz

Typical Configurations

  • 01

    Sealed-Tank Transformer

    Hermetically sealed oil-immersed transformer configuration designed to limit contact between insulating oil and the external atmosphere.
  • 02

    Conservator-Type Transformer

    Oil-immersed transformer equipped with a conservator system for oil volume compensation and project-specific protection and monitoring arrangements.
  • 03

    Project-Specific Configuration

    Transformer ratings, connection arrangements, accessories, protection and monitoring arrangements configured according to project requirements.

Technical Specifications

Parameter Specification
Primary Rated Voltage Up to 35 kV
Secondary Voltage 0.4 / 0.415 / 6.6 / 10 / 11 kV / Other Voltages on Request
Transformer Capacity 100 kVA – 10 MVA
Rated Frequency 50 / 60 Hz
Phase Three-Phase
Cooling Method ONAN / ONAF
Insulating Liquid Mineral Oil
Vector Group Dyn11 / Yyn0 / Other Vector Groups on Request
Tap Arrangement Off-Circuit Tap Changer / Other Tap Arrangements on Request
Impedance Voltage According to Transformer Rating & Project Requirements
Insulation Level According to Rated Voltage & Applicable Standards
Temperature Rise According to Applicable Standards / Project Requirements
Loss Requirements According to Project Specifications
Tank Configuration Sealed / Conservator Type
Installation Indoor / Outdoor
Applicable Standards IEC 60076 Series

Standards, Testing & Documentation

IEC-Oriented Design

IEC-Oriented Design

Designed according to applicable parts of the IEC 60076 series and project specifications.

Factory Routine Testing

Factory Routine Testing

Routine tests are carried out before shipment according to applicable parts of the IEC 60076 series and project specifications.

Project Documentation

Project Documentation

Technical datasheets, drawings and test records can be provided for project review.

Download Product Catalogue

Discuss Your Transformer Requirements

Share your system voltage, transformer capacity, primary and secondary voltage, installation conditions and project specifications with our engineering team.

return-top

    Need a quote for your project?

    Share your requirements and our team will typically respond within 1 business day.

    Fields marked with an * are required.

    Full Name *

    Email Address *

    Company Name

    Country / Region *

    WhatsApp / Mobile

    Project Requirements / Message *

    WeChat

    WeChat QR Code

    Scan to Chat

    Open WeChat and scan to connect