Side-Mounted Vacuum Circuit Breaker

TOONICE side-mounted vacuum circuit breakers are designed for switching, protection and control in 12 / 17.5 / 24 kV medium-voltage systems. The side-mounted structure enables flexible integration into compact switchgear layouts and project-specific installation arrangements.

Key Ratings

  • Rated Voltage

    12 / 17.5 / 24 kV

  • Rated Current

    Up to 1600 A

  • Rated Short-Circuit Breaking Current

    Up to 31.5 kA

  • Installation

    Fixed Side-Mounted

  • Applicable Standard

    IEC 62271-100

Vacuum Interrupter & Pole Design

  • Vacuum Interrupter

    Vacuum Interrupter

    The vacuum interrupter is the core switching element inside the pole, providing current switching and fault interruption in a sealed vacuum environment.

  • Insulated Pole Design

    Insulated Pole Design

    Vacuum interrupters and primary conductive parts are supported and insulated by separate insulating components for reliable medium-voltage insulation and mechanical support.

  • Embedded Pole Design

    Embedded Pole Design

    Vacuum interrupters and primary conductive parts are encapsulated in epoxy resin as an integrated pole structure, providing enhanced insulation reliability and environmental resistance.

Side-Mounted Installation

Side-Mounted Installation

Designed with a lateral mounting arrangement, with left- or right-hand configurations available to suit different switchgear layouts. The operating mechanism and primary circuit are arranged for compact switchgear integration.

Mounting points and primary connection interfaces can be configured according to switchgear layout and project requirements.

Side-Mounted Vacuum Circuit Breaker

Technical Specifications

Parameter Specification
Rated Voltage 12 kV 17.5 kV 24 kV
Rated Frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Rated Current Up to 3150 A Up to 3150 A Up to 2500 A
Rated Short-Circuit Breaking Current Up to 40 kA Up to 40 kA Up to 31.5 kA
Rated Short-Time Withstand Current Up to 40 kA Up to 40 kA Up to 31.5 kA
Power-Frequency Withstand Voltage 28 kV 38 kV 50 kV
Lightning Impulse Withstand Voltage 75 kV 95 kV 125 kV
Operating Sequence O – 0.3 s – CO – 15 s – CO
Mechanical Endurance 10,000 operations
Installation Fixed / Withdrawable
Applicable Standard IEC 62271-100

Note: Available ratings depend on voltage class, pole design, installation configuration and product series.

Standards, Testing & Documentation

IEC-Oriented Design

IEC-Oriented Design

Designed with reference to IEC 62271-100 and applicable project requirements.

Factory Routine Testing

Factory Routine Testing

Electrical, mechanical, operating and applicable interlocking checks are carried out before shipment according to product configuration.

Project Documentation

Project Documentation

Technical datasheets, outline drawings, wiring diagrams and test records can be provided for project review.

Download Product Catalogue

Discuss Your Side-Mounted Vacuum Circuit Breaker Requirements

Share your system voltage, rated current, breaking capacity, installation requirements and switchgear interface requirements with our engineering team.

return-top

    Need a quote for your project?

    Share your requirements and our team will typically respond within 1 business day.

    Fields marked with an * are required.

    Full Name *

    Email Address *

    Company Name

    Country / Region *

    WhatsApp / Mobile

    Project Requirements / Message *

    WeChat

    WeChat QR Code

    Scan to Chat

    Open WeChat and scan to connect