NSRM-7.2

NSRM-7.2 SF6 gas-insulated ring main unit

NSRM-7.2 gas insulated enclosed metal switchgear is mainly used in 7.2KV urban core distribution network scenarios and is a key equipment for urban ring networks, commercial complexes, and data centers. It is characterized by compactness and intelligence, adapting to the distribution needs of high load density areas, and helping to build a “strong, reliable, self-healing and efficient” modern urban power grid. The equipment adopts an ultra-thin modular design, with a cabinet width of only 800mm, saving 30% of the floor space compared to traditional switchgear. It is particularly suitable for limited space scenarios such as urban underground pipe galleries and commercial buildings. Supporting “dual ring network+self-healing” configuration, it can achieve automatic fault location and isolation, greatly reducing power outage time.

Contact Us phone

Features

1. Space optimization, adapted to restricted scenarios

2. Good insulation arc extinguishing effect, safe and reliable operation

3. Intelligent self-healing operation and maintenance to improve power supply efficiency

4. Wide range environment adaptation, strong scene compatibility

5. Modular combination, flexible and convenient expansion

The NSRM-7.2 inflatable sulfur hexafluoride fully insulated ring main unit has passed the “self-healing ring network” special test of the State Grid, with built-in intelligent terminals and fiber optic longitudinal differential protection. The fault response time is less than 20ms, and it can achieve “second level self-healing” of the distribution network. For scenarios such as data centers that require extremely high power continuity, the equipment is equipped with dual power automatic switching function, with a switching time of less than 50ms, ensuring zero interruption of core loads. In order to adapt to the digital transformation of urban power grid, the equipment supports the deployment of 5G edge computing nodes, which can collect real-time distribution network operation data, predict failure risks in combination with AI algorithm, and upgrade the operation and maintenance mode from “passive emergency repair” to “active early warning”. At present, it has been widely applied in core business districts such as Beijing CBD and Shanghai Lujiazui, becoming a benchmark product for urban power grid upgrading.

Let’s Get Started

Providing you with the most trusted energy solutions in an unpredictable world.

Contact Us

Request an Insurance Quote

    Specification

    Item Unit Model C Model F Model V Model CB
    Rated voltage kV 7.2 7.2 7.2 7.2
    Rated frequency Hz 50 50 50 50
    Power frequency withstand voltage (phase to phase/port) kV 20/23 20/23 20/23 20/23
    Lightning impulse withstand voltage kV 40/46 40/46 40/46 40/46
    Rated current A 630 630/1250 630/1250
    Rated closed-loop breaking current A 630 630
    Rated cable charging breaking current A 135 135
    Rated short-circuit closing current (peak) A 50 80 50 50
    Rated peak withstand current A 50 50 50
    Rated short-time withstand current kA/3s 20 20 20
    Rated short-circuit breaking current kA 20 31.5 20 25
    Rated transfer current A 1750
    Maximum current of equipped fuse A 125
    Circuit resistance -n ≤300 ≤600 ≤300 ≤300
    Mechanical lifespan times 5000 5000 5000 5000

    FAQs

    Does SF6 gas pose environmental risks? How to deal with a leak?

    Although SF6 gas has a high greenhouse effect potential, the annual leakage rate of the equipment gas chamber is ≤ 0.01%, and the leakage amount is extremely low and controllable; Equipped with a density controller with temperature compensation function in daily operation, it can monitor gas pressure in real time and alarm promptly when leaks are detected. After the leakage, professional personnel need to use specialized equipment to recover the gas and avoid direct discharge. At the same time, the leakage points (welds, sealing rings, pipeline connections, etc.) should be inspected and repaired, and qualified SF6 gas should be replenished.

    What is the maintenance cycle and core maintenance content of the equipment?

    The equipment air chamber is designed to be maintenance free. The core maintenance is concentrated on the secondary components and mechanical mechanisms, and the regular maintenance cycle is 1-2 years. The main content includes checking whether the density controller indication is normal, whether the secondary wiring is firm, the operating status of components such as contactors and position indicators, and the flexibility of the mechanical interlocking mechanism. It does not require frequent unpacking and maintenance, and the maintenance cost is significantly lower than that of traditional switchgear.

    How to solve the problem of excessive moisture in the equipment?

    If the moisture content of SF6 gas exceeds the standard value (≤ 150 μ L/L), the SF6 gas can be directly replaced or dried if it slightly exceeds the standard value; When the exceedance is severe, it is necessary to first evacuate the gas chamber, replace the adsorbent, and then inject qualified SF6 gas that has been dried. At the same time, investigate the pathways of moisture infiltration (such as aging of seals, damage to the gas chamber, etc.) to avoid repeated problems.

    Can the device adapt to different altitudes and temperature environments?

    It can adapt to environments with an altitude of ≤ 5000m (please specify in advance if the altitude exceeds 2000m for customization and optimization), with a temperature adaptation range of -50 ℃ to+50 ℃. It can cope with extreme environments such as high temperature, severe cold, high altitude and low pressure, without the need for additional heat dissipation or insulation devices, and is widely applicable to different climate regions.

    What are the core differences between Q5 and traditional air insulated switchgear?

    The core differences are reflected in three aspects: first, space occupation. This device has reduced its size by more than 30% and is suitable for space limited scenarios; The second is insulation performance. SF6 gas has higher insulation strength, is less affected by the environment, and has a lower failure rate; The third is the operation and maintenance cost. The maintenance free design of the gas chamber significantly reduces the workload of maintenance, and the self-healing function reduces power outage losses, making it more cost-effective in the long run.

    Does the equipment comply with relevant industry standards?

    It fully complies with multiple national and international standards, including GB/T3906-2020 “3.6kV~40.5kV AC Metal Enclosed Switchgear and Control Equipment”, IEC62271-200:2011, GB/T1022-2020, etc. It has passed type test certification, and all performance indicators meet industry standards, making it safe to connect to various power grid systems.

    Related Applications

    Urban core distribution network scenario
    Suitable for core distribution network nodes such as urban ring main units, switch stations, and small substations, it can adapt to the power supply needs of high load density areas. With its self-healing function, it ensures the overall stability of the urban power grid, reduces large-scale power outages caused by line failures, and assists in the construction of modern smart grids.

    Commercial and Civil Building Scenarios
    Suitable for limited space scenarios such as commercial complexes, high-rise buildings, office buildings, and large supermarkets, the 800mm narrow cabinet design can be flexibly embedded in the building’s power distribution room. With excellent safety performance and low-noise operation characteristics, it can meet the dual requirements of commercial buildings for power supply reliability and environmental adaptability.

    Data center and precision load scenarios
    As a key power distribution equipment in data centers, IDC rooms, and precision instrument production workshops, it can provide uninterrupted power supply guarantee. The fault self-healing function can minimize the duration of power outages and avoid damage to precision equipment due to power outages. The SF6 gas insulation characteristics can adapt to the operating requirements of enclosed environments in computer rooms.

    Special spaces and complex environmental scenes
    Suitable for special spaces such as urban underground pipe galleries, tunnels, and underground mines, as well as power distribution needs in high-altitude areas, coastal areas with high salt spray, and humid and rainy areas, the sealed structure and anti-corrosion design can effectively resist harsh environmental erosion and ensure long-term stable operation of equipment.

    New energy supporting scenarios
    The booster box type substation and collection station that can be applied to new energy projects such as photovoltaics and wind power can adapt to the fluctuating demand of new energy generation, support distributed energy access, and ensure the safe grid connection and transmission of new energy power through intelligent control and high reliability.

    return-top

      Need a quote for your project?

      Please fill out the form below and we'll contact you as soon as possible.

      Fields marked with an * are required

      Name *

      Email *

      Your Products *

      Your Country *

      Message *