XGN12
The 12kV air-insulated ring main unit is a high-voltage compact equipment in the medium-voltage distribution network, primarily designed to meet the 12kV distribution needs of power system hubs, super-large industrial enterprises, and high-end new energy projects. Utilizing air as the insulating medium, it integrates a high-strength insulation structure, large-capacity current-carrying design, and intelligent linkage technology. It possesses core functions such as main line power supply, ring network interconnection, large load access, and rapid fault clearance. The equipment combines high-voltage adaptability with spatial compactness, enabling centralized control of high-voltage distribution networks within limited spaces. It serves as a crucial hub equipment connecting high-voltage distribution networks with medium and low-voltage loads.
The insulation structure has undergone multiple reinforcement treatments, withstanding the test of 12kV high-voltage insulation. With a rated current up to 3150A and a short-circuit breaking current of up to 40kA, it can accommodate the needs of extremely large load access and high-current transmission on main lines.
Compared to traditional open-type equipment of the same voltage level, the cabinet volume is reduced by more than 55%. The layered layout optimizes space utilization, allowing direct installation in underground distribution rooms, high-rise building power distribution rooms, and other space-constrained scenarios, significantly reducing construction costs.
It supports deep linkage with power grid dispatching systems, new energy control platforms, and enterprise production dispatching systems. It possesses functions such as power quality analysis, load forecasting, and remote precise regulation and control, enabling refined management and unmanned operation and maintenance of the distribution network.
The core components are made of military-grade aging-resistant materials, and the sealing structure adopts a dual-channel waterproof and dustproof design. The mean time between failures (MTBF) is over 120,000 hours, supporting frequent operation and adapting to the continuous operation requirements of high-voltage distribution networks.
Execution standards: GB/T 3906-2020, IEC 62271-201; Rated current: 1600A-3150A; Short-circuit breaking current: 31.5kA-40kA; Protection level: IP4X (IP55 for outdoor type); Installation methods: Indoor floor-mounted, outdoor prefabricated (integrated with box transformer), embedded in underground distribution room; Optional configurations: Vacuum circuit breaker, power quality monitoring module, fire linkage device, intelligent energy storage operating mechanism.
Providing you with the most trusted energy solutions in an unpredictable world.
Contact Us| No. | Name | Unit | Value |
| 1 | Rated Voltage | kV | 12 |
| 2 | Rated Frequency | Hz | 50 |
| 3 | Rated Current of Main Busbar / Maximum Rated Current of Fuse | A | 630, 125 |
| 4 | Rated Short-time Withstand Current of Main Circuit & Grounding Circuit | kA/S | 20, 3 |
| 5 | Rated Peak Withstand Current of Main Circuit & Grounding Circuit | kA | 50 |
| 6 | Rated Short-circuit Making Current of Main Circuit & Grounding Circuit | kA | 50 |
| 7 | Full Capacity Opening Times of Load Switch | times | 100 |
| 8 | Fuse Breaking Current | kA | 31.5 |
| 9 | Rated Closed-loop Breaking Current | A | 630 |
| 10 | Rated Transfer Current | A | 1600 |
| 11 | Mechanical Life | times | 2000 |
| 12 | 1min Power Frequency Withstand Voltage (Peak) – Phase-to-Phase & Phase-to-Earth / Isolation Break | kV | 28/32 |
| 13 | Lightning Impulse Withstand Voltage (Peak) – Phase-to-Phase & Phase-to-Earth / Isolation Break | kV | 75/85 |
| 14 | 1min Power Frequency Withstand Voltage of Secondary Circuit | kV | 2 |
| 15 | Protection Class | IP3X |
The core advantage is its compact size, which allows it to fit into the narrow space of distribution rooms in high-rise buildings. It also boasts excellent sealing and anti-condensation performance, enabling it to withstand the humid environment of underground distribution rooms in high-rise buildings. Its intelligent features allow for remote operation and maintenance, reducing the frequency of manual inspections.
Fully compatible, it can be customized with anti-islanding protection and harmonic suppression linkage functions, and can stably accommodate the fluctuating load of new energy generation. Additionally, it features high-voltage insulation redundancy, effectively resisting voltage surges during the grid connection of new energy, and ensuring the power quality of the distribution network after grid connection.