NSGTG-22
The 22kV solid insulated ring main unit is a high-performance equipment designed for rail transit, overseas specific distribution networks, and domestic high-end industrial special needs. It adopts electromagnetic compatibility strengthening and anti vibration optimization epoxy resin integrated casting technology, fully sealed and encapsulated high-voltage core components, strictly following domestic and foreign standards such as IEC 62271 and EN 50124, and is suitable for rail transit traction auxiliary power supply, overseas high-end distribution networks, and industrial heavy-duty special distribution needs under the 22kV voltage level. The product has the characteristics of strong electromagnetic compatibility, excellent vibration resistance, high degree of customization, and reliable operation, and is the core guarantee equipment for 22kV distribution network in special scenarios.
Optimize the electromagnetic shielding structure and wiring design of the cabinet, pass EN 50124 electromagnetic compatibility certification, can resist strong electromagnetic interference generated by rail transit traction systems, ensure stable operation of equipment in strong electromagnetic environments, and eliminate signal interference hazards.
The cabinet adopts a reinforced anti vibration structure, and key components are equipped with buffering devices. It has passed the anti vibration level test of rail transit and can operate stably under frequent vibration and impact conditions, adapting to severe vibration scenarios such as rail transit and mining.
Protection levels, operating mechanisms, monitoring modules can be customized according to the special needs of rail transit, overseas distribution network, and industry. It supports specialized modifications such as traction auxiliary power supply interfaces, multilingual controllers, and explosion-proof, and is suitable for multiple special scenarios.
Optimize the design of the switch mechanism, with a response time of ≤ 30ms for opening and closing, supporting rapid switching of emergency backup power supply, ensuring uninterrupted power supply for critical loads such as rail transit and important industries, and reducing downtime losses due to faults.
using anti-aging and arc resistant epoxy resin formula, the service life of insulation components is ≥ 35 years, combined with modular design, easy maintenance, maintenance cycle is extended by 3 times compared to equipment of the same level, and the operation and maintenance costs throughout the life cycle are reduced by more than 35%.
Execution standards: IEC 62271-200, EN 50124, GB/T 11022, CE/T Ü V certification; Rated parameters: rated current 1250A-1600A, rated short-circuit breaking current 31.5kA-40kA, rated short-time withstand current 40kA/4s, protection level IP55-IP65, suitable for 50Hz/60Hz dual frequency; Material configuration: arc resistant and anti-aging epoxy resin, oxygen free copper conductor, reinforced anti vibration cabinet body; Customized services: support for rail transit traction auxiliary interfaces, electromagnetic shielding upgrades, multilingual controllers, and anti vibration reinforcement improvements.
Providing you with the most trusted energy solutions in an unpredictable world.
Contact Us| Name | Unit | Parameter | |||
| Rated voltage | kV | 22 | |||
| Rated frequency | Hz | 50 | |||
| Current rating | A | 630 | 1250 | ||
| Rated insulation level | Power frequency withstand voltage | Fracture | kV | 60 | |
| Fireline to Fireline | kV | 50 | |||
| Fireline to ground | kV | 50 | |||
| Withstand voltage for lightning impulses | Fracture | kV | 145 | ||
| Fireline to Fireline | kV | 125 | |||
| Fireline to ground | kV | 125 | |||
| Rated short-circuit interrupting current(1s) | kA | 20 | 25 | ||
| Rated short-time withstand current(4s) | kA | 20 | 25 | ||
| Rated peak withstand current(1p) | kA | 50 | 63 | ||
| Rated short-circuit closing current (peak)(1ma) | kA | 50 | 63 | ||
| Enclosure rating | IP4X | ||||
| Operating mode | Spring-loaded energy storage | ||||
Yes, it has passed the EN 50124 electromagnetic compatibility certification. The electromagnetic shielding structure can effectively resist strong electromagnetic interference from the traction system, and will not interfere with the rail transit signal system, adapting to the traction auxiliary power supply requirements.
The anti vibration level meets the IEC 60068-2-6 standard, and can cope with vibration impacts with frequencies of 10Hz-150Hz and accelerations of 2g. It is suitable for severe vibration conditions such as rail transit train operation and mining equipment operation.
Support, customizable 50Hz/60Hz dual frequency adaptation version, targeted optimization of core electrical component parameters, can be integrated into overseas 22kV distribution network systems with different frequencies without additional adjustments.
Fully satisfied, with a response time of ≤ 30ms for opening and closing, capable of achieving second level switching between main and backup power sources, ensuring uninterrupted power supply for critical loads such as rail transit and important industries, and no voltage fluctuations during the switching process.
Easy to replace, modular design allows for quick disassembly and replacement of aging insulation components without the need for overall disassembly of the cabinet; The original spare parts supply is sufficient, and the replacement cost is only about 12% of the total equipment price. After replacement, the original performance of the equipment can be restored.